Find support for your Discover user manuals, FAQs, hints & tips for your Philips product. GAGGIA SYNCRONY LOGIC J SILVER. LOGIC UL. INSTRUCTIONS MANUAL GAGGIA UL. GAGGIA SUPR. Gaggia Syncrony logic SUP Manual. This is original manufacturer’s file as a onetime Free downloadable with any purchase. The file will be emailed.

Author: Gardabar Grorg
Country: Costa Rica
Language: English (Spanish)
Genre: Politics
Published (Last): 7 February 2006
Pages: 324
PDF File Size: 6.40 Mb
ePub File Size: 9.64 Mb
ISBN: 335-6-41466-883-1
Downloads: 70996
Price: Free* [*Free Regsitration Required]
Uploader: Kagajar

Alternatively you can try frothing on the machine without the pannarello attachment.

The pannarello should be taken apart frequently and the separate parts should be soaked in some hot water to help remove any built-up milk residues. While the brew unit is removed, the brew unit chamber should be wiped down with a moist cloth to remove excess grounds and coffee residues. After you have descaled, run tanks of plain water through the hot water function for the wand in order to ensure the system is completely free of debris.

The finer direction is indicated by lower numbers. One useful trick the the bypass function allows for is that you can do a quick rinse of the brew circuit by simply running a bypass cycle and not adding any preground coffee.

Gaggia Syncrony Logic Manuals

The manua below shows proper frothing technique:. If you are having difficulty frothing then the cappuccinatore attachment or the steam wand it connects to may need to be cleaned. Whole Latte Love Support Library.

While this is true of other styles of espresso machine, this is not true of a super-automatic unit. Do not add whole beans, or entire bags of preground coffee into this chamber. To avoid this, it is imperative to keep a regular maintenance schedule. Ceramic cups will sap a lot of heat from the shot resulting in a colder shot. Your machine features a brew unit cleaning cycle.

When Super-Automatic machines are in operation the brew unit will make a few different noises which are normal. Poor shots can also be the result of incorrect grind settings. This should be done on a monthly basis; refer to your manual for instructions on how to run one.

  KOCHANOWSKI TRENY EBOOK

The Gaggia Syncrony Logic RS is a super-automatic espresso machine which features a rapid boiler system. This error typically indicates the machine is not being cleaned on a regular basis. The spout needs to be positioned under this tube to properly gahgia the coffee through the spouts. Please check the position of this gaggua as shown in this troubleshooting document:.

The machine utilizes a vibration style pump. Super-automatic machines utilize heat and pressure as part of the brewing process, which is key to espresso brewing. As a result, even though water is flowing through the machine, you will get a flow error. The most important thing to understand about Super-Automatic machines is that they do not accept oily, caramelized, or flavored beans. In this section we will walk you through the most important points of the machine setup.

Forced removal of the brew unit can cause the gavgia to fail in a way that will only be able to be repaired by professional technician. It is also important to use plain water; detergents and soaps should not be used.

If you think your wand is producing too much steam, or your milk looks like it is boiling, then you may need to make an adjustment to your frothing technique. To start, the video below provides five useful tips to help you understand your manua machine:.

There is a tube that dispenses coffee from the brew unit. The video below identifies these mistakes and shows how to syncgony them:.

Gaggia Syncrony Logic – Whole Latte Love Support Library

Alternatively you can use the machine’s hot water function to fill the cup with hot water before pulling a shot to preheat it.

Once the flow issue has been resolved the machine should be immediately descaled with the recommended product. Make sure the machine is powered on when doing these maintenance items. This machine also utilizes a special nozzle attachment called a pannarello. If the machine is within the specified steam test range, then the machine is producing the correct amount of steam and an adjustment to frothing technique is necessary.

  MARMA POINTS OF AYURVEDA VASANT LAD DOWNLOAD

The machine is now ready to brew for drinks, but the startup settings may not match the drink you are trying to brew. Using a carafe that is chilled in a freezer before frothing is helpful for keeping the milk cooler for longer, allowing for more time to froth before the milk begins to scald. There is a device in the machine called a flow meter, and it tells the machine when water is flowing through or not.

The machine manual provides a thorough walk-through of the set-up of the unit, but there’s so much information it can be mystifying.

A food safe silicone-based lubricant should be used, such as food grade Petrol-Gel. The machine achieves this through a device called a brew unit.

SYNCRONY LOGIC RS Machine Manual.pdf

It is likely that scale has built lkgic inside the valve, and the buildup is holding the valve open. There are also common frothing mistakes which are made that will result in poor or no froth. Instead, this indicates that an adjustment needs to be made in the brewing process or that different beans need to be used.

If the machine is not powered on the sensors won’t reset and the alarm light will remain on.